Слайд 12
Repair Technique-Measure Audio Voltage 3-1 3-2 Use Multi-Meter to measure AUD
+5V & 3.3V.
P.S. Audio +5V is transferred by small
regulator like 78L05 (+12V to AUD+5V)
Слайд 13
Repair Technique-Measure Audio Clock 4-1 4-2 Use Oscilloscope to measure Audio
CLK 24.576Mhz (from X’TAL) or 14.318Mhz (from CLK Generator)
Слайд 14
Repair Technique-Measure Audio signals 5 Use Multi-Meter to measure other
Audio signals’ bias voltage value. (This method should be